You seem to be 'Offline'

Change Language
eMonitoring Technologies Dual Chanel Vibration Transmitter, eMT800-02
eMonitoring Technologies Dual Chanel Vibration Transmitter, eMT800-02

eMonitoring Technologies Dual Chanel Vibration Transmitter, eMT800-02

ईमोनिटरिंग टेक्नोलॉजीज़ ड्यूल चैनल वाइब्रेशन ट्रांसमीटर, eMT800-02

50,000 / Set

by: EMonitoring Technologies, Mumbai

Get Contact
Get Best Price

Product Description

Brand
EMonitoring Technologies
Model
EMT800-02
Application
Industrial
Output
Isolated 4-20 MA DC With Max Load Of 600 Ohms Per Channel RS485 Modbus RTU, Wireless Or GSM Conne
Display
7 Segment 4 Digit 12.5mmH Bright LED Display Per Channel
Measurement
Acceleration 0-19.99 G (Pk Or RMS) Or Velocity 0-199.9 Mm/s (Pk Or RMS) Or Displacement 0-1999 Mic
Accuracy
Full Scale
Enclosure
ABS.plastic Moulded OR IP65 OR Flame Proof
Mounting
Panel Mounted Or Field Mounted
Power Supply
110V / 230V Selectable Or 90 To 260 VAC-DC & 24Vdc(optional)
Signal Input
Piezo Accelerometer 2 Wire CC, Piezo Velocity 2 Wire CC Or Loop Powered Sensor
Sensor Power
24 V DC @ 4 MA Constant Current Or +24 V DC Loop Power
Alarm & Trip
Alarm & Trip Levels Are Independently Programmable Over Full Scale Range Relay Contacts 1 C/O,
Channels
1 To 2
Frequency Response
5 Hz 10KHz 3 DB For Acceleration
Minimum Order Quantity
1 Set

In order to keep pace with the never-ending demands of customers, we are involved in offering a wide range of Dual Chanel Vibration Transmitter.
Other Details:
The eMT800 Vibration Transmitter (1 or 2 Channel) is microprocessor based fully programmable device, designed to meet industrial environment and is very reliable and accurate employing the latest technology. All the units undergo stringent tests to assure quality performance. Large Fans and Blowers (ID, FD, SA, PA etc.) are used in process plants for moving air or gases; they are essential for cooling, heating or transporting product. They usually are centrifugal or axial driven and commonly develop erosion and/or corrosion and/or deposition on the blades. This results in a progressive increase in vibrations. And build-up of dirt or cake on a fan’s impellor is quite normal. However, not always are these faults progressive and predictive but, should a dirt piece become detached then suddenly the rotor becomes out of balance, and if ignored, consequential damage to the drive motor’s bearings and coupling will result. This can be extremely destructive and threaten personnel and plant safety. The loss of a single line Fan or Blower can shut down the process causing significant production and financial losses. The re transmission analogue signal can be trended in DCS/PLC to monitor defect progression and plan maintenance considering production schedule and fix the problem before catastrophic failure. RS485 Modbus RTU or GSM or RS232 connectivity is also available as an option.
Recomonded Measurement Positions:

Locating the vibration sensors as indicated in the schematic will be most sensitive and effective in detecting the above faults listed. The sensor orientations are summarised as follows:

  • HORIZONTAL on two motor bearings (A & B) and two fan bearings (C&D). B&C ideally recommended
  • VERTICAL on motor & fan drive end bearings (B&C).
  • AXIAL on motor & fan drive end bearings (B&C). B or C is recommended

Detailed Brochure

Get Latest Price for your requirement >
View More

About the Seller

EMonitoring Technologies

eMonitoring Technologies Dual Chanel Vibration Transmitter, eMT800-02

Get Contact
Get Best Price
Bhandup West, Mumbai
68% Call Pick Up Rate
Trustseal Verified
Nature of Business
Manufacturer
Delivery Locations
All Over India
View More

Contact this seller

eMonitoring Technologies Dual Chanel Vibration Transmitter, eMT800-02

I agree to terms and privacy policy
  • Mumbai

Find nearby sellers for Vibration Transmitters

  • Mumbai
Looking for something else ?

Get best deals for

Vibration Transmitterson the go!

4.6
Open in App